Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Nephrol ; 51(7): 511-519, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32659755

RESUMO

BACKGROUND: Arteriovenous (AV) fistulas are considered the gold standard for ensuring safe and long-term vascular access in patients with haemodialysis-dependent end-stage renal disease. However, previous studies demonstrated that high-flow AV fistulas might add additional cardiovascular burden in the post-transplant setting, leading to frequent fistula closure in this population. Currently, there is no consensus regarding management of high-flow fistulas in post-transplant patients with stable kidney function. The present randomized controlled trial examines the effect of prophylactic AV fistula closure on high-output heart failure. METHODS: Twenty-eight kidney transplant patients with stable graft function, absence of pre-existing severe cardiac failure, and brachial arterial flow rate of at least 1,500 mL/min were recruited and randomized in a 1:1 ratio to an intervention and control group, respectively. The intervention group was subject to immediate fistula ligature. Patients within the control group were referred to fistula ligature only if the main study endpoint high-output heart failure was reached. The latter was defined by the presence of at least 1 clinical sign (i.e., worsening NYHA score) and at least 2 of the following echocardiographic parameters: diameter of right atrium (major) >53 mm, right atrium (minor) >44 mm, inferior vena cava ≥21 mm, right pulmonary artery >20 mm, TAPSE <16 mm, systolic pulmonal artery pressure >40 mm Hg, and/or left ventricular eccentricity index <1. During a 24-month follow-up period, quarterly measurements of kidney function, NT-proBNP, and lactate dehydrogenase as well as a biannual echocardiographic check-up were performed. RESULTS: High-output heart failure attributable to high-flow fistula was reported in 5 of 13 control patients (38.5%), whereas no patient in the intervention group presented with clinical and echocardiographic signs of high-output heart failure during the follow-up period. Thus, prophylactic ligature of high-flow fistulas avoided high-output heart failure in our patient population (p = 0.013). Three patients in the control group, however, had to undergo fistula ligature due to aneurysm formation (n = 2) and steal phenomenon (n = 1). Median NT-proBNP levels decreased from 317 ng/L pre-ligature to 223 ng/L post-ligature (p = 0.003). Serum creatinine levels did not significantly differ before and after AV fistula ligature (1.69 vs. 1.60 mg/dL, respectively, p = 0.059). Improvement of echocardiographic findings (e.g., a decrease in systolic pulmonary arterial pressure) was found in 7 of 8 ligature patients but did not reach statistical significance. CONCLUSION: Prophylactic ligature of high-flow AV fistulas after kidney transplantation can avoid high-output heart failure, and a more liberal approach to close AV fistulas might be justified.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Insuficiência Cardíaca/epidemiologia , Transplante de Rim/efeitos adversos , Ligadura/métodos , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos Profiláticos/métodos , Adolescente , Adulto , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/prevenção & controle , Humanos , Falência Renal Crônica/terapia , Ligadura/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Procedimentos Cirúrgicos Profiláticos/estatística & dados numéricos , Estudos Prospectivos , Fluxo Sanguíneo Regional , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Tempo para o Tratamento/estatística & dados numéricos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...